The Mark
Grivitei Sud, Bucharest
Description
The Mark is one of Bucharest CBD’s most prestigious office developments located in close proximity to Victoriei Square and next to the Uranus Boulevard.
The Victoriei Square has always played a significant role in the rise of Bucharest - an economic, social and cultural magnet that draws people to live and work in the area. The area stands at the heart the city’s vital community.
The Mark is situated in the center of the city and, therefore, offers all the advantages of an urban lifestyle. Employees can reach the location comfortably and conveniently. They work in a modern, inspiring office and can enjoy the cosmopolitan and vibrant atmosphere of the area during breaks or after work.
The location is next to the city's central business district and easily accessible by car. It takes only a few minutes walk to the city centre. The nearby underground station and several tram stations are just a minute away. There are also quick connections to the airport and other business districts.
SPECIFICATIONS
SUMMARY - TOWER
- 15 floors above ground and 3 basements.
- A wide variety of high efficient and low energy service installations coupled with a climate-responsive façade to reduced energy consumptions of the building.
- Single-storey Entrance Hall with 5.1m floor to ceiling height.
- Central core with 5 passenger lifts, 1 combined passenger, goods and fire lift, 1 scissor staircase and 1 male and 1 female washroom per floor (including facilities for disabled persons).
- Passenger lifts from Entrance Hall to 15th floor (maximum rated capacity up to 1,600kg each, at 2.5m/s). A VIP access from the 1st basement would be possible.
- Passenger/ freight and fire lift serving 1st basement to roof level (maximum rated capacity up to 2,000kg, at 2.5m/s).
- 2 car park shuttle lifts (630kg, at 1.6 m/s) from 2nd basement to Entrance Hall only.
- BMS controlled of central HVAC and security systems.
- Elevators, doors and entrance barriers are secured by personalised access cards.
- Electronic fire detectors and sprinkler systems throughout the offices.
- Floor sizes between 200sqm up to 856 sqm per level (occupant areas).
- Possible connection to the Podium building via bridges.
- 1.35m planning grid with services positioned to allow for flexible and efficient office partitioning.
- 3.0m floor to ceiling height (4.025m floor to floor)
- General floor loading of 3.0kN/sqm live load + 1kN/sqm
- Enhanced floor loadings of 10kN/sqm to certain areas.
- Excellent natural lighting with additional external glare shield and sun heat-load protection by special external blinds.
- Full accessible raised floor - 250mm clear void
- Four pipe fan coil air conditioning (ceiling mounted units).
- Ventilation provision 5.8 m³/h per usable area (approximately 2 air changes per hour) distributed by pressurised raised access floor.
- Each tenant's cooling, heating and power consumption is individually metered.
- Life safety back-up power supply via standby generator
- Targeting "Excellent" Breeam rating
- 300 underground car spaces and additional 45 spaces in the outside area (serving the Tower and Podium together).

Violetta